![Installation](/images/new-backgrounds/123095/12309527x1.webp)
D9210B
Installation
3.2.2Pulling and Marking the Wires
Running wire. Use Table 4 to estimate the wire bundle size for your knockouts and where to mount the D9210B. Tag your wire runs to prevent confusion during installation and troubleshooting. Figure 2 shows the wiring for a typical D9210B installation.
| Suggested | Approximate | Recommended Wire | Recommended | |
Purpose | Wire Tag | Diameter | Type | Color Code | |
Power/SDI data | Tag A | 0.25 in. | 4/22 AWG quad | SDI: | A |
|
| (6.4 mm) | (2500 ft. / 762 m) | (Green) |
|
|
|
| 4/18 AWG quad | (Yellow) | B |
|
|
| (5000 ft. / 1,524 m) |
| |
|
|
|
| Pwr: | + (Red) |
|
|
|
|
| - (Black) |
|
|
|
|
| |
RTE power/input* | Tag B | 0.25 in. | 4/22 AWG quad | Green/Black | |
|
| (6.4 mm) |
|
|
|
REX power/input* | Tag C | 0.25 in. | 4/22 AWG quad | Yellow/Black | |
|
| (6.4 mm) |
|
|
|
Strike power* | Tag D | 0.375 in. | Red |
| |
|
| (9.5 mm) |
|
|
|
Door contact* | Tag E | 0.125 in. | 2/22 AWG | White |
|
|
| (3.2 mm) | (500 feet / 152 m) |
|
|
|
|
|
|
| |
Reader* | Tag F | 0.375 in. | 6/22 AWG | 12 VDC: Red | |
|
| (9.5 mm) | conductor | 5 VDC: Orange | |
|
|
| (500 feet / 152 m) | COM: Black | |
|
|
|
| ||
|
|
|
| D1: White | |
|
|
|
| D0: Green | |
|
|
|
| LED: Brown | |
|
|
|
| Buzzer: Yellow | |
Buzzer* | Tag G | 0.125 in. | 2/22 AWG twist | +(Red), - (Blk) | |
|
| (3.2 mm) |
|
|
|
Emergency Exit* | Tag I | 0.125 in. | 2/18 AWG twist | Blue |
|
|
| (3.2 mm) |
|
|
|
|
|
|
|
|
|
Power Supply | Tag J | 0.25 in. | 2/18 AWG zip | Brown |
|
Transformer |
| (6.4 mm) |
|
|
|
|
|
|
|
|
|
* Be sure to multiply the wires by the number of D9210Bs in the enclosure.
Table 4: Typical Wire Planning Chart for the D9210B
D9210B Operation and Installation Guide
32206G | Page 14 | © 2002 Bosch Security Systems |