Installation
3.2.10 Setting the Dipswitch and Tagging the Unit
The D9412 panel supports up to eight door controllers using all eight address settings. The D7412 supports up to two door controllers using the first two address settings. Each D9210B uses one of eight addresses. Addresses can not be duplicated. Because the D9210B is always supervised, two D9210B modules having the same address will not function and SDI failures will occur.
Fill out the Program Record Sheet. Be sure the program record sheet for this door controller contains the area assignment, address assignment and control center assignment.
Whenever possible, be consistent when numbering doors, control centers, and areas. This will help when programming a system with more than one door. (Example: Assign Door 1 to Area 1 and Control Center 1.)
Technical
Tip
The D9210B dipswitch with factory default settings (all ON) is shown in Figure 4. Table 8 shows the serial device reporting address settings for each door controller. Table 8 also shows dipswitch settings for Test and Fail modes.
|
|
|
|
|
| Figure 4: D9210B DIP Switch | ||
|
|
|
|
|
| (Factory Settings) |
| |
|
|
|
|
|
|
|
|
|
|
| Door Controller Address |
| Fail |
|
| ||
|
|
| Mode |
|
| |||
|
| 1 | 2 |
| 3 | 4 | 5* | 6* |
Serial Device |
|
|
|
|
|
|
|
|
Control Center Display | Central Station |
|
|
|
|
|
|
|
| Modem IIIa2 |
|
|
|
|
|
|
|
D9210 #1 | SDI #33 | ON | ON |
| ON | |||
D9210 #2 | SDI #34 | OFF | ON |
| ON | |||
|
|
|
|
|
|
|
|
|
D9210 #3 | SDI #35 | ON | OFF |
| ON | |||
D9210 #4 | SDI #36 | OFF | OFF |
| ON | |||
D9210 #5 | SDI #37 | ON | ON |
| OFF | |||
D9210 #6 | SDI #38 | OFF | ON |
| OFF | |||
D9210 #7 | SDI #39 | ON | OFF |
| OFF | |||
D9210 #8 | SDI #40 | OFF | OFF |
| OFF | |||
SDI Fail Mode |
|
|
|
|
|
|
|
|
SDI Fail – Door Unlocked |
|
| ON | |||||
SDI Fail – Door Locked |
|
| OFF |
* Switches 5 and 6 must stay in the “ON” position
Table 8: D9210B Dipswitch Settings