![](/images/new-backgrounds/1165613/16561353x1.webp)
ATM/POS Bridge | Configuration Using HyperTerminal en 27 |
|
|
–Bridge Name: Type an optional name for the bridge in the Bridge Name input box. This name facilitates recognition of the bridge on the network.
–IP Address: Displays the current IP Address for the bridge. Select option 2 to enter a new IP Address.
–Subnet Mask: Displays the current Subnet Mask for the bridge. Select option 3 to enter a new Subnet Mask.
–Default Gateway: Displays the current Gateway Address for the bridge. Select option 4 to enter a new Gateway Address.
–Recorder TCP Port: Displays the TCP port number where the recorder listens for the bridge device. You can type a new port number in the input box.
–Service TCP Port: Displays the TCP port where the bridge listens for CLI commands. (The bridge supports CLI commands which are used to read and change settings in the bridge). Select option 6 to enter a new port number.
–Tx Server TCP Port: Displays the TCP port number where the bridge listens for the server that receives transaction data from the POS or ATM devices on the network. Select option 7 to enter a new port number.
–Device Detection: Enables or disables the Bridge Detection utility to find the bridge on a network.
NOTICE!
It is recommended to disable this feature once the network settings are configured.
–MAC Address: Displays the MAC Address for the bridge. This value cannot be changed.
Bosch Security Systems, Inc. | Installation Manual | F.01U.171.816 1.0 2010.09 |