ATM/POS Bridge

Configuration Using HyperTerminal en 29

 

 

6.3.3Terminal Setup

The Terminal Setup pages allow you to configure the bridge to accept transactions from the devices connected to the bridge.

Select a terminal number to configure the settings for that terminal.

Name: Select option 1 to type an optional name for the terminal. This name facilitates recognition of the terminal on the network

Device: Select the type of POS or ATM device. You can choose one of these options:

Specific Device: The bridge converts the characters from the terminal based on the code page setting of the terminal and the recording language selected on the bridge System menu.

Transparent: The bridge receives all characters from an ATM/POS terminal in a complete line without protocol conversion; then transmits the complete line to a recording device. The bridge does not perform character conversion.

Capture: The bridge receives all characters from an ATM/POS terminal one character at a time; then transmits an individual character to a recording device. The bridge does not perform character conversion.