[_ CHECKFOR LEAKS
When all connections have been made, make sure all cooktop controls are in the OFF position and turn on the main gas supply valve. Use a liquid leak detector at all joints and connections to check for leaks in the system.
CAUTION: DO NOT USE A FLAME TO I CHECK FOR GAS LEAKS.
When using test pressures greater than 1/2 psig to pressure test the gas supply system of the residence, disconnect the cooktop and individual
[_ CHECK QUALITY OF FLAMES
The combustion quality of burner flames needs
to be determined visually.
(A) Yellow
(B) Yellow tips on outer
Normal for LP gas
(C) Soft blue
If burner flames look like (A), call for service. Normal burner flames should look like (B) or (C), depending on the type of gas you use.
With LP gas, some yellow tipping on outer cones is normal.
J-_ FINAL STEPS
Fill in the date plus the name and address of the
service organization performing the conversion
in the spaces provided on the conversion label. Remove the backing from the label and stick it in
a convenient place on the underside of the cooktop near the Rating Plate. Make sure the area is clean and dry before applying the label.
The conversion is now complete.