LTC 8016/90 Instruction Manual Installation
4.6Allegiant Series Switcher Data Interface
4.6.1Allegiant Interface Configurations
When using the Allegiant data interface protocol, up to 31 Interface Units can be connected to a single large Allegiant system. In this configuration, bi- directional Bilinx communication to physical cameras ranging from 1 to 496 is supported. In very large systems, additional units can be interfaced to the Allegiant via biphase data connection.
When connecting to an Allegiant system, select a data port on the main Allegiant CPU that will be used to communicate with the Interface Unit. The Interface Unit provides separate interface connectors so it is able to support both
Only one port on the Interface Unit can be used at a time. Connecting data cables to more than one port on the Interface Unit simultaneously could result in
4.6.1.1 Allegiant Interface Port Selection
Based on the Allegiant model being used, select an available CPU port from the table below. Note that it is not possible to connect the Interface Unit cable to a Console port provided by an Allegiant LTC 8712 Series Port Expander accessory unit.
Allegiant |
| Supported Ports |
|
| |
Model | CONSOLE | PRINTER | ALARM1 | COM1 | COM2 |
|
|
|
|
|
|
LTC 8100 | YES | NO | NO | NO | NO |
|
|
|
|
|
|
LTC 8200 | YES | NO | NO | NO | NO |
LTC 8300 | YES | YES | NO | NO | NO |
|
|
|
|
|
|
LTC 8500 | YES | YES | YES | NO | NO |
|
|
|
|
|
|
LTC 8600 | YES | YES | YES | YES | YES |
|
|
|
|
|
|
LTC 8800 | YES | YES | YES | YES | YES |
|
|
|
|
|
|
LTC 8900 | YES | YES | YES | YES | YES |
|
|
|
|
|
|
The ALARM port requires a special cable pinout. DO NOT USE the supplied cable for this port connection. A cable must be constructed by the installer, per the pinouts shown in the CONNECTOR & CABLE PINOUTS Section.
4.6.1.2Setting the Allegiant System to Use Bilinx Communication Mode
Using Allegiant Keyboard User Function 39, a system keyboard operator with Level 1 Priority must configure the Allegiant to enable the communication interface on the selected port.
EN 14
IntuiKey Series Keyboard:
From the main Allegiant screen, navigate to the User Functions menu screen, then press [Enter User Command]. Key in 39, then press [Enter].
LTC 8555 or LTC 8550 Series Keyboard: Press [USER], key in 39, then press [Enter].
The monitor’s
The port is now configured with the proper baud rate and handshake settings to communicate with the Interface Unit.
001 PASSWD REQ'ED 12:00:00 |
|
|
| ||
NO DIU OPERATION |
|
|
| ||
BOSCH |
|
|
|
|
|
| POWER |
|
|
|
|
LTC 8016/90 | Allegiant Data | 001 PASSWD REQ'ED 12:00:00 | |||
Interface Unit | NO DIU OPERATION | ||||
Interface Protocol | BOSCH |
| |||
|
|
| |||
|
|
|
| ||
|
|
|
|
| BOSCH |
Typical Allegiant |
|
| 1 | 2 | 3 |
|
| 4 | 5 | 6 | |
|
| 7 | 8 | 9 | |
|
| 0 |
|
| |
|
|
|
|
| |
System Main CPU Bay |
| IntuiKey | |||
ALLEGIANT Video Matrix | BOSCH |
| |||
|
| ||||
|
|
| Keyboard |
Figure 6 Allegiant
If the
(i.e., having CPU modules with a single
A system reset is required to complete the process. Either use Keyboard User Function 15, or power off/on the main Allegiant CPU bay. The Allegiant is then ready to communicate with the Interface Unit.
Bosch Security Systems 18 August 2005