LTC 8016/90 Instruction Manual Maintenance | EN 21 |
|
|
| |
|
|
Pin | Connection |
|
|
1 | |
|
|
2 | RXD+ |
3 | |
|
|
4 | TXD+ |
5 | |
|
|
6 | |
7 | |
8 | |
9 | |
|
|
8.2 Supplied Serial Data Cable Pinouts
1
24
35
42
53
6
7
8
9
8.3 Miscellaneous Cables (Not supplied)
Bosch S1385 or Industry standard Null modem
(PC COM Port) | (LTC 8016 PC) |
1,6 | 4 |
|
|
2 | 3 |
3 | 2 |
|
|
4 | 1,6 |
5 | 5 |
|
|
7 | 8 |
8 | 7 |
9 | |
|
|
1The PC connector on units manufactured before July, 2004 (date code 0426) used a male
Industry type straight through
(DVR COM Port) | (LTC 8016 PC Port) |
1 | 1 |
2 | 2 |
3 | 3 |
4 | 4 |
5 | 5 |
6 | 6 |
7 | 7 |
8 | 8 |
9 | 9 |
|
|
2The PC connector on units manufactured before July, 2004 (date code 0426) used a male
(Alarm Port) | (LTC 8016 | ||
1 | RTS | 3 | CTS |
|
|
|
|
2 | Tx | 5 | Rx |
3 | Chassis Gnd |
| |
|
|
|
|
4 | Data Gnd | 1 | Data Gnd |
5 | Data Gnd | 7 | Data Gnd |
6 | Rx | 4 | Tx |
7 | CTS | 2 | RTS |
8 | No Connection |
| |
9 | No Connection |
|
9.0MAINTENANCE
The Allegiant Bilinx Data Interface Unit does not require any special maintenance.