Bosch Appliances LTC 8016/90 instruction manual En, Bosch Security Systems 18 August

Models: LTC 8016/90

1 24
Download 24 pages 2.78 Kb
Page 10
Image 10
Manual background

LTC 8016/90 Instruction Manual Installation

EN 10

 

 

4.4.1Group ID Settings When Using Allegiant RS-232 or RS-485 Protocol

When using the Allegiant data interface protocol, the Group ID must be set to correspond to a block of 16 physical camera numbers between 1-16 and 481-496. Since each block consists of 16 numbers, the Group ID number for these cameras ranges from 1 to 31. Select a Group ID number that does not duplicate another Group ID number.

A special case exists when multiple units are cascaded using the Interface Unit’s RS-485 data connection (explained later). The left-most Group ID switch on the last unit must be set to 9, to terminate the data link.

For example, if a total of 32 Bilinx-enabled cameras will be connected using the range of Allegiant inputs 17-32 and 49-64, one of the Interface Units must be set to Group ID 002, and the other to 004. If the Interface Unit for cameras 49-64 is the last unit connected at the end of the RS-485 data link, its actual Group ID should be set to 904.

If only one Interface Unit will be connected to support Bilinx cameras on inputs 1 to 16, no change is required from the Interface Unit’s default setting of 901.

Set the Group ID switches using the supplied screwdriver, as follows:

Group ID

Camera

Group ID

Camera

Switches1

Number

Switches1

Number

 

Range

 

Range

 

 

 

 

001

1 to 16

017

257 to 272

002

17 to 32

018

273 to 288

 

 

 

 

003

33 to 48

019

289 to 304

 

 

 

 

004

49 to 64

020

305 to 320

 

 

 

 

005

65 to 80

021

321 to 336

 

 

 

 

006

81 to 96

022

337 to 352

 

 

 

 

007

97 to 112

023

353 to 368

 

 

 

 

008

113 to 128

024

369 to 384

 

 

 

 

009

129 to 144

025

385 to 400

 

 

 

 

010

145 to 160

026

401 to 416

 

 

 

 

011

161 to 176

027

417 to 432

 

 

 

 

012

177 to 192

028

433 to 448

 

 

 

 

013

193 to 208

029

449 to 464

 

 

 

 

014

209 to 224

030

465 to 480

 

 

 

 

015

225 to 240

031

481 to 496

 

 

 

 

016

241 to 256

 

 

 

 

 

 

1The last unit must be set to terminate the RS-485 data line, by setting the left-most Group ID switch to 9.

If the Allegiant’s camera number assignments will be changed (using the Allegiant Master Control Software package) to use logical camera numbers other than the default physical input numbers, Interface Units with Group ID ranging from 1 to 31 are automatically notified of the new settings, by the Allegiant system. This allows the system to support random camera numbers.

NOTE: If the Allegiant’s logical camera number assignments are changed as described above, then downloaded into the Allegiant CPU, the update process may take up to 30 seconds. Camera control functions will not be available until this update has completed.

Bosch Security Systems 18 August 2005

Page 10
Image 10