IP Camera 200 Series | Advanced Mode en 93 |
|
|
The camera connects to all remote stations protected by the same general password. To define a general password:
1.Select 10 in the Number of destination IP address list box.
2.Enter 0.0.0.0 in the Destination IP address field.
3.Enter the password in the Destination password field.
4.Set the user password of all the remote stations to be accessed using this password.
Setting destination 10 to the
Video transmission
If the device is operated behind a firewall, select TCP (HTTP port) as the transfer protocol. For use in a local network, select
UDP.
Please note that in some circumstances, in the event of an alarm, a larger bandwidth must be available on the network for additional video images (if Multicast operation is not possible). To enable Multicast operation, select the UDP option for the Video transmission parameter here and on the Network page.
Stream
Select a stream to be transmitted.
Remote port
Select a browser port, depending on the network configuration. The ports for HTTPS connections are only available if the On option in SSL encryption is selected.
Video output
If it is known which device is being used as the receiver, select the analog video output to which the signal should be switched. If the destination device is unknown, it is advisable to select the First available option. In this case, the image is placed on the first free video output. This is an output on which there is no signal. The connected monitor only displays images when an alarm is triggered. If a particular video output is selected and a split image is set for this output on the receiver, select the decoder from Decoder in the receiver that is to be used to
Bosch Security Systems | Installation and Operation Manual |