12 en Connection and mounting

DINION 5000 AN

 

 

4Connection and mounting

CAUTION!

Before proceeding, disconnect the power from the power supply cable. Ensure that the voltage of the unit matches the voltage and type of the power supply being used.

4.1Power connection

4.1.1Low voltage cameras

VIDEO

1

+

12VDC

24VAC

5 mm

Figure 4.1 Low voltage power connection

Connect power from a 24 VAC or 12 VDC class 2 power supply as follows:

Use AWG16 to 22 stranded wire or AWG16 to 26 solid wire; cut back 5 mm (0.2 in) of insulation.

Remove the 3-pole connector from the camera body.

Loosen the screws and insert the wires.

Note

The central connection for System (video) ground is optional. Connecting System ground to Safety ground may result in ground loops that can disrupt the CCTV system.

Tighten the screws and reconnect the 3-pole connector to the camera.

AM18-Q0644 v1.0 2013.03

Installation Manual

Bosch Security Systems

Page 12
Image 12
Bosch Appliances VBN-5085 installation manual Connection and mounting, Power connection, Low voltage cameras