5.5.2Exposure submenu

Item

Selection

Description

 

 

 

ALC level

-15 to +15

Selects the video level range. A

 

 

positive value is more useful for low-

 

 

light conditions; a negative value is

 

 

more useful for very bright

 

 

conditions.

 

 

Some ALC adjustment may improve

 

 

scene content when Smart BLC is

 

 

enabled.

 

 

 

ALC speed

Slow,

Adjusts the speed of the video level

 

medium, fast

control loop. For most scenes it

 

 

should remain at the default value.

 

 

 

Shutter

AES, FL, Fixed

AES (auto-shutter) - the camera

 

 

automatically sets the optimum

 

 

shutter speed.

 

 

FL - flickerless mode avoids

 

 

interference from light sources

 

 

(recommended for DC-iris lenses

 

 

only).

 

 

FIXED - allows a user defined shutter

 

 

speed.

 

 

 

Default (AES)

1/50 (PAL)

In DEFAULT (AES) mode, the camera

shutter

1/60 (NTSC),

tries to maintain the selected shutter

or

1/100 (PAL)

speed as long as the light level of the

Fixed shutter

1/120 (NTSC),

scene is high enough.

 

1/250,

In Fixed mode, selects shutter

 

1/500,

speed.

 

1/1000,

 

 

1/2000,

 

 

1/4000,

 

 

1/10K,

 

 

1/100K

 

 

 

 