DINION 5000 AN

Connection and mounting en 15

 

 

4.3Alarm and relay connector

 

ALARM

 

1

4

 

2

5

5 mm

 

 

3

6

(0.2 in)

 

Figure 4.4 Alarm and relay connector pins

Pin

Alarm socket

 

 

1

Alarm in

 

 

2

not used

 

 

3

Relay out contact 2

 

 

4

Alarm in ground

 

 

5

not used

 

 

6

Relay out contact 1

 

 

Max. wire diameter AWG 22-28 for both stranded and solid; cut back 5 mm (0.2 in) of insulation.

Alarm output relay switching capability: Max voltage 30VAC or +40 VDC. Max 0.5 A continuous, 10 VA.

Alarm in: TTL logic, +5V nominal, +40 VDC max, DC coupled with 22 kOhm pull-up to +3.3 V.

Alarm in: configurable as active low or active high.

Max. 42 V allowed between camera ground and each of the relay pins.