ENVIRONMENTAL

ENVIRONMENTAL

 

 

Environment

Low temperature, indoor/outdoor

Operating Temperature

-50° to 122°F (-46° to 50°C); de-ices to 25°F (-4°C)

Thermostat Operation

Heater is thermostatically controlled to activate < 41°F (< 5°C)

CAMERA

 

 

Service Connector

3-conductor, 2.5 mm connector for video output to optional ICS-SC cable

Imaging Device

1/3-inch imager

 

Picture Elements

NTSC

PAL

DW/CW

720 (H) x 540 (V)

720 (H) x 540 (V)

DN/CH

768 (H) x 494 (V)

752 (H) x 582 (V)

Dynamic Range

 

 

DW/CW

102 dB typical/120 dB maximum

Signal System

NTSC or PAL

 

Scanning System

 

 

DW/CW

2:1 interlace/progressive scanning (DIP switch selectable)

DN/CH

2:1 interlace

 

Synchronization

Internal

 

Electronic Shutter Range

Auto (1/15 to 1/22,000)

LENS

 

 

Type

Varifocal with auto iris

Focal Length

3.0 mm ~ 9.5 mm

 

 

9.0 mm ~ 22.0 mm

 

Format Size

1/3-inch

 

Operation

 

 

Iris

Auto (DC drive)

 

Focus

Manual

 

Zoom

Manual

 

Ø5.50

(13.97)

3.63

3.03

(9.22)

(7.70)

5.28

(13.41)

Ø3.79

(9.63)

NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.