Pelco C3432M-F manual ALARM AND 24 VAC WIRES, Connecting A Relay Device, Description

Models: C3432M-F

1 40
Download 40 pages 39.89 Kb
Page 15
Image 15
ALARM AND 24 VAC WIRES

ALARM AND 24 VAC WIRES

 

Table B. Wire Descriptions

 

 

 

Wire Color

 

Description

 

 

 

Black

 

24 VAC (use only if PoE is not connected)

 

 

 

Red

 

24 VAC (use only if PoE is not connected)

 

 

 

Blue

 

Alarm In

 

 

 

Blue/White

 

Alarm In, Return

 

 

 

Green

 

Relay Out

 

 

 

Green/White

 

Relay Out, Return

 

 

 

CONNECTING A RELAY DEVICE

The IP110 Camclosure has an output for triggering an external device. It supports both momentary and continuous relay operation.

You can operate the relay interactively, during an active connection, or automatically to coincide with certain events. Typical applications include activating a door, gate or lock, or switching on lights or other electrical devices.

WARNING: Do not exceed the maximum rating of 12 VDC, 0.15 A.

Figure 9 shows how to wire the relay with its power source to the Camclosure.

CONNECTING A RELAY DEVICE

(CONNECTION EXAMPLE)

DC

GREEN WIRE

GREEN / WHITE WIRE

_ +

Figure 9. Relay Wiring

NOTE: The green/white wire is internally connected to the camclosure chassis. Any connected signalling device should be left floating with respect to the camclosure chassis, otherwise damage could result.

C3432M-F (6/08)

15

Page 15
Image 15
Pelco C3432M-F manual ALARM AND 24 VAC WIRES, Connecting A Relay Device, Description