System | eMix Application |
|
|
|
|
4.2.6Monitor Patching
The monitor outputs are automatically routed to the MC524 Monitor Controller sup- plied with System
Click on the Console I/O category and the Monitor Busses
Monitor | Busses | Format |
|
|
|
Control Room | L, C, R, Sl, Sr, Bm, X, Y | |
|
|
|
Mon A | L, C, R, Sl, Sr, Bm, X, Y | |
|
|
|
Mon B | L, R | |
|
|
|
Mon C | L, R | |
|
|
|
Mon D | L, R | |
|
|
|
Table
The Cascade inputs allow for direct bus injection prior to the insert point into all mon- itor signal paths.
4.2.7Solo Bus and Utility Patching
The Solo Busses
The Utility Sources
4.2.8Talkback Signal Patching
The two talkback mics are wired to the MC524 Monitor Controller. They are summed and amplified to produce a single talkback signal. This analog signal must be fed into the system through an AM713 Analog to MADI converter.
To send talkback to the busses, this signal must be patched to the Slate Input (in the Utility Destinations subcategory of the Console I/O category). Note which AM713
47