System | GPI/O Event System |
|
|
|
|
11.9GPI Examples
Refer to Figure
If an event consists of just one input, AND and OR deliver the same result and may be used interchangeably.
11.9.1Move a Fader to Turn Off the Floor Monitors
This example demonstrates how to turn off the floor monitors by moving any one of several faders above a selected level.
1.In the Event Configuration window, under Event List, click on the <click to add event> field.
The Add Event dialog appears.
2.Select Or as the logical operator from the dropdown menu.
3.Under Input, click on the <click to add input> field. The Add Input Event dialog appears.
4.Select Fader from the dropdown menu and click OK.
5.Configure the Input Properties to the following settings:
Channel # | 1 |
Activation level (dB) | |
Activation Type | Above |
6.Repeat steps
7.Under Output, click on the <click to add output> field. The Add Output Event dialog appears.
8.Select Control Room from the dropdown menu and click OK.
9.Configure the Output Properties to the following settings:
Action | Monitor A |
Active State | Off |
143