Sum or Intercancel

The Σ key is inactive (not lit) by default, which means that selecting a new source automatically cancels the previous one. When the Σ key is lit, multiple sources can be se- lected simultaneously. The Σ symbol appears to the left of the first source selected in the LCD display in the monitor controls. After selecting multiple sources, pressing the Σ key again (so it is not lit) does not deselect theses sources until a new source is explicitly selected.

Follow Control Room Monitors

Activate the FlwCR key so the Mon A–D outputs follow the source selected for the Control Room monitors.

5.1.2Main Section and Aux Send Format

Each Main section also has a return that allows Bus/Tape monitoring. The returns can be patched from the record machine’s outputs using PatchNet (see Main Bus Send/Re- turn on page 46). It is not possible to select a Main section and its return at the same time; they intercancel even in Summing mode.

Aux Sends appear in the Panel as mono or stereo pairs.

5.1.3Control Room Monitor Controls

Press the CR Output key above the CR Source LCD to display the Control Room Out- put Panel (Figure 5-4).