System 5-B Digital Audio Mixing System Operation Manual

eMix Application

 

 

 

 

Figure 4-9shows the lower part of the Console I/O window. The Selected: area shows the sources and destinations for the A Input and B Input cells selected above. The numbered tabs (1–48 etc.) display additional pages of patchpoints. The four buttons on the right of Figure 4-9perform the following functions:

Patch: Makes a connection between selected patchpoints

Unpatch: Breaks the connection between selected patchpoints

Clear: Deselects selected patchpoints

View Log: Shows a log of failed patches

Figure 4-9Bottom of Console I/O window

4.2.2Device Inputs and Outputs

There are up to 12 MADI device input/output ports on the console, each carrying up to 56 channels (44.1/48 kHz) or 28 channels (96 kHz).

NOTE: To clarify the use of the terms Inputs and Outputs in PatchNet, Device per- tains to equipment other than the System 5-B console. Therefore, Device In- puts refers to inputs to an external device, not the console.

4.2.3Cabling

This category handles MADI cable connections for the ML530 Mic/Line Interfaces.

Mic/Line Interface Patching

For mic inputs and analog inputs not at +4 dB, the Euphonix ML530 provides 24 preamps each with gain, phantom power, high-pass filter, and hiZ/loZ switching. The analog outputs are connected to an AM713 Analog to MADI converter which then con- nects to one of the MADI inputs on the SH612 Studio Hub.

41

Page 41
Image 41
Euphonix 5B operation manual Device Inputs and Outputs, Cabling, Mic/Line Interface Patching