DSDA iSCSI Disk Array SeriesAdding Storage en 19
6.1.3 | Connecting the Shelf |
| 4. Connect the shelves using the supplied cables. |
| – For the first shelf: |
| Insert an SFP into the In port of each of the two I/O modules at the back of the shelf |
| to convert them to optical ports, making sure that the SFP has the correct position |
| before inserting it. |
| Plug in one end of the optical cable to the In port of the lower I/O module on your |
| shelf. |
| Plug the other end into the Fibre Channel (FC) port labeled 0a on the storage con- |
| troller. |
| Connect one end of the second optical cable into the In port of the upper I/O mod- |
| ule of your shelf. |
| Connect the other end to the second FC port on your storage system, labeled 0b. |
| – For additional shelves: |
| Insert an SFP into the In port of each of the two I/O modules at the back of the shelf |
| to convert them to optical ports, making sure that the SFP has the correct position |
| before inserting it. Repeat this for the Out port of the last shelf in your existing loop. |
| Connect one end of the |
| new disk shelf. |
| Connect the other end to the Out port of the upper I/O module of the last shelf in |
| your existing loop. |
| Connect one end of the |
| new disk shelf. |
| Connect the other end to the Out port of the lower I/O module of the last shelf in |
| your existing loop. |
|
|
| NOTICE! |
i | It might take up to 60 seconds for the storage system to recognize the new disks. |
The procedure as described above is only valid for new disk shelves. If you want to assign disk | |
shelves that have already been used by a different storage controller, please refer to the | |
| original NetApp documentation. |
|
|
5.Log in to the FilerView administration interface as described in Section 5 Configuration through the Web Interface, page 8.
6.In the navigation panel, select Storage > Disks > Manage and verify that the system shows the new disks, i.e. View Type is set to Spare Disks.
| i | NOTICE! |
| If you are using the VRM Video Recording Manager application (Version 1.5 or higher), all | |
|
| |
|
| further settings are made through VRM. |
|
| If you use the digital storage systems for direct recording, continue with the following steps. |
|
|
|
6.1.4 |
| Adding New Volumes |
7.In the navigation panel, select Volumes > Add.
Click Next in the welcome screen of the Volume Wizard.
8.Volume Type Selection: Set to Traditional. Click Next.
Bosch Security Systems | Installation Guide | V 1 2008.08 |