DSDA iSCSI Disk Array Series

Monitoring and Maintenance en 29

 

 

1.Upload the new software to a Web server

If you are using VRM, place the file that contains the new version in

C:\Program Files\Bosch\Video Recording Manager\VRM Server\web on your VRM Server.

If you are not using VRM, start a Web server tool, for example MiniWebServer.exe, select a root directory and copy the new software version into this root directory. Example screen:

2.Download and install the new version on the storage controller hard disks:

Connect to the console of the storage device. To connect to the console, select Filer > Use Command Line in the navigation panel of the FilerView administration interface.

If you are using VRM: On the console, enter

software install http://username:password@<VRM Server IP>/ <Filename>

Replace <username> and <password> with the login information of your VRM server. Replace <VRM Server IP> with the IP address of your VRM server and <Filename> with the name of the file that contains the new version.

Wait a few minutes for the installation to complete.

If you are using MiniWebServer.exe:

On the console, enter software install http://<MiniWebServer>/<filename> and replace <filename> with the name of the software update file.

Wait until the success message displays: Installation of setup.exe-7.xxx_e.exe completed.

3.Download the new software to the CF card: On the console, enter: download.

Wait until the success message displays: Operator requested download completed.

4.On the console, enter: halt.

The system reboots and stops at the bootloader.

Note that no data can be written on the disks while the system is rebooting.

Bosch Security Systems

Installation Guide

V 1 2008.08