DSDA iSCSI Disk Array SeriesTechnical Data en 31

8

Technical Data

 

 

 

 

 

For more detailed information, please refer to the data sheets with the latest information

 

 

available on

 

 

 

 

 

www.boschsecurity.com under Product Catalog > CCTV > IP Video > Disk Arrays.

8.1

Technical Specifications DSA-S5B50

8.1.1

Electrical Requirements

 

 

 

 

 

 

 

 

 

 

 

AC power/Max current

100 V to 120 VAC, 9 A

 

 

 

 

 

 

 

 

 

 

 

200 to 240 VAC, 4.5 A

 

 

 

 

 

 

 

 

 

 

Frequency

50/60 Hz

 

 

 

 

 

 

 

 

 

 

Heat dissipation BTU/h

1706 BTU, fully loaded

 

 

 

 

 

 

 

 

8.1.2

System Hardware Specifications

 

 

 

 

 

 

 

Chassis

2U, 19”-rack-mountable

 

 

 

 

 

 

 

 

 

 

Power supplies

Dual redundant, hot pluggable

 

 

 

 

 

 

 

 

 

 

Disk drives

Up to 12: 1 TB SATA-II drives

 

 

 

 

 

 

 

 

 

 

Max raw capacity

12 TB

 

 

 

 

 

 

 

 

 

 

DDR2 memory (system RAM)

2048 MB

 

 

 

 

 

 

 

 

 

 

Nonvolatile SDRAM (NVRAM)

256 MB—protects “in flight” transactions

 

 

 

 

 

for 3 days in the event of a power

 

 

 

 

 

loss

 

 

 

 

 

 

 

 

 

 

Integrated I/O

2 x 10/100/1000 Gigabit Ethernet,

 

 

 

 

 

copper

 

 

 

 

 

 

 

 

8.1.3

Mechanical

 

 

 

 

 

 

 

 

 

 

Height

89 mm (2 U) (3.5 in (2 U))

 

 

 

 

 

 

 

 

 

 

Width

447 mm (17.6 in)

 

 

 

 

 

 

 

 

 

 

Depth

508 mm (20 in)

 

 

 

 

 

 

 

 

 

 

Weight

35.8 kg (52 lb), fully loaded

 

 

 

 

 

 

 

 

8.1.4

Space Requirements

 

 

 

 

 

 

 

 

 

Front clearance

268 mm (10.55 in)

 

 

 

 

 

 

 

 

 

Rear clearance

414 mm (16.3 in)

 

 

 

 

 

 

 

 

8.1.5

Environmental

 

 

 

 

 

 

 

 

 

 

 

Temperature

 

 

 

 

 

 

 

 

 

 

• operating range

0 °C to +40 °C (+32 °F to +104 °F)

 

 

 

 

 

 

 

 

 

• storage range

-10 °C to +65 °C (-40 °F to +149 °F)

 

 

 

 

 

 

 

 

 

 

Relative humidity

 

 

 

 

 

 

 

 

 

 

• operating range

20 to 85%, non-condensing

 

 

 

 

 

 

 

 

 

• storage range

20 to 95%, non-condensing

 

 

 

 

 

 

 

 

 

Operating acoustic noise

66 dBA at 1 m at +23 °C

 

 

 

 

 

 

 

 

Bosch Security Systems

Installation Guide

V 1 2008.08