Specifications
| Control Timings |
| ||
Ignition State |
|
|
| Timing |
15 seconds |
|
|
| |
Trial for Ignition | 90 seconds |
|
|
|
Flame Stabilization Period | 3 seconds |
|
|
|
15 seconds |
|
|
| |
Flame Failure Response Time | 1.5 seconds (2 second maximum, 1 second minimum) | |||
15 seconds |
|
|
| |
PS Fault Delay (failed open/close) | Retry after 2 minutes |
| ||
Soft Lockout | Retry after 5 minutes |
| ||
TCO Limit Lockout | Indefinite (see page 34 to reset) | |||
Verify Resistive Delay | Retry after 2 minutes (repeats 5 times) | |||
Simulated Resistive Load Lockout | Indefinite (cycle power to reset) | |||
Hardware Error Lockout | Indefinite (self clears if fault clears for at least 15 seconds) | |||