Flammable Vapor Sensor Testing
Flammable vapor
sensor harness
Flammable vapor
sensor harness

Flammable Vapor Sensor Testing

Gas Control Assembly to the Thermal Well (cont’d)

Step 8. To resume operation, follow the instructions located on the water heater lighting instruction label. Or, use the lighting instructions located in the water heater installation and operating manual.

Flammable Vapor Sensor Testing

115 VAC Circuit Trace CAUTION

Do not use standard multi-meter probes for this testing. Doing so will damage the connector. Use special pin type electronic probes or small diameter wire pins inserted into connector.

Step 1. Move the gas control power switch to the “OFF” position.

Gas control power

switch

Step 2. Disconnect the flammable vapor sensor harness from the gas control.Manual background

Step 3. Using a multi-meter set to the ohms setting, measure the resistance of the flammable vapor sensor and resettable ther- mal switch. The resistance must be between 3,000 and 48,000 ohms. If the resistance is out of this range, verify that the re- settable thermal switch has not been tripped. If it hasn’t,

the thermal switch.

115 VAC Circuit Trace

Step 1. Verify 115VAC and proper polarity are at the wall outlet.

Step 2. With the water heater plugged in and the gas control power switch in the “ON” position verify LED status.