Bradford-White Corp U1TW60T*FRN Blower Temperature Switch Testing cont’d, Page, Switch Setting

Models: U1TW40S*FRN U2TW65T*FRN UTW450S60FR*N U1TW60T*FRN UTW465S60FR*N U1TW50S*FRN U2TW50T*FRN

1 52
Download 52 pages 26.11 Kb
Page 32
Image 32
Blower Temperature Switch Testing (cont’d)

Blower Temperature Switch Testing

Blower Temperature Switch Testing (cont’d)

Switch Setting

Opens on rise @ approximately 165oF

Auto resets on fall @ approximately 160oF

Cool switch to

below 160oF

Disconnect wire leads to

 

 

 

 

 

switch. Using multi-meter set

N

Replace switch

 

to the ohms setting. Is there

 

 

 

 

 

(see page 33).

 

continuity between the switch

 

 

 

 

 

 

 

 

terminals?

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

 

 

 

N

 

 

Reconnect wire leads and ob-

Y

 

 

 

 

serve heater operation. Do

 

Do switch

Y

Exhaust

 

 

exhaust gas temperatures

 

 

contacts

 

temperature

rise to or above 170oF with

 

 

open?

 

is too hot.

vent connected?

 

 

 

 

 

 

N

 

 

 

 

 

 

Do switch con-

Y

Replace switch

 

 

 

 

 

tacts open?

 

 

(see page 33).

 

 

N

Switch OK

Common causes for high

exhaust temperature

1.Vent length is below mini- mum allowable

2.Vent diameter not to speci- fication

3.Restricted dilution air inlet

4.Missing or deteriorated flue baffle

5.Gas pressure is out of specification

Page 32

32

Page 32
Image 32
Bradford-White Corp U1TW60T*FRN, UTW450S60FR*N, U2TW50T*FRN Blower Temperature Switch Testing cont’d, Page, Switch Setting