Inner Door Gasket Replacement
Step 6. Remove the connectors attached to the re- settable thermal switch on the manifold mount.
| Flammable vapor |
Inner Door Removal Procedure (cont’d) | sensor clip |
|
Step 7. Remove the flammable vapor sensor from the clip by pushing down on the tab to open the clip.
Flammable vapor
sensor
Step 8. Inspect both inner doors for any of the following imperfections: tears, missing material, cracks, dirt or debris, lack of adhesion to the inner door, material left
WARNING
If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death.
on combustion chamber, or any other imperfections that will inhibit a proper seal.
If any of the imperfections above are present, door gasket following the Inner Door Gasket Replacement Procedure. If not, replacement of the inner door gaskets is not necessary.
Inner Door Gasket Replacement Procedure
Gasket overlap must be
as shown ± 1/32
replace the inner
Enlarged
view of
flange
area
Step 1. Completely remove all gasket and adhesive residue from the right and left side inner doors, as needed.
Recommended pattern for RTV sealant Step 2. |
| U s i n g |
|
RTV | sealant, |
| |
apply a 1/8” |
| ||
bead to secure |
| ||
Slice gasket here to slide over burner venturi t h e | Gasket overlap must be |
| |
| as shown ± 1/32 | Expanded view |
Page 47