Bradford-White Corp U1TW40S*FRN, UTW450S60FR*N, UTW465S60FR*N Inner Door Gasket Replacement

Models: U1TW40S*FRN U2TW65T*FRN UTW450S60FR*N U1TW60T*FRN UTW465S60FR*N U1TW50S*FRN U2TW50T*FRN

1 52
Download 52 pages 26.11 Kb
Page 47
Image 47
Inner Door Gasket Replacement

Inner Door Gasket Replacement

Step 6. Remove the connectors attached to the re- settable thermal switch on the manifold mount.

 

Flammable vapor

Inner Door Removal Procedure (cont’d)

sensor clip

 

Step 7. Remove the flammable vapor sensor from the clip by pushing down on the tab to open the clip.

Flammable vapor

sensor

Step 8. Inspect both inner doors for any of the following imperfections: tears, missing material, cracks, dirt or debris, lack of adhesion to the inner door, material left

Inner Door Removal Procedure (cont’d)WARNING

If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death.

on combustion chamber, or any other imperfections that will inhibit a proper seal.

If any of the imperfections above are present, door gasket following the Inner Door Gasket Replacement Procedure. If not, replacement of the inner door gaskets is not necessary.

Inner Door Gasket Replacement Procedure

Gasket overlap must be

as shown ± 1/32

replace the inner

Enlarged

view of

flange

area

Step 1. Completely remove all gasket and adhesive residue from the right and left side inner doors, as needed.

Recommended pattern for RTV sealant Step 2.

 

U s i n g

 

RTV

sealant,

 

apply a 1/8”

 

bead to secure

 

Slice gasket here to slide over burner venturi t h e

Gasket overlap must be

 

 

as shown ± 1/32

Expanded view

Page 47