Bradford-White Corp U2TW65T*FRN, UTW450S60FR*N, UTW465S60FR*N Anode Inspection and Replacement

Models: U1TW40S*FRN U2TW65T*FRN UTW450S60FR*N U1TW60T*FRN UTW465S60FR*N U1TW50S*FRN U2TW50T*FRN

1 52
Download 52 pages 26.11 Kb
Page 45
Image 45
Anode Inspection

Anode Inspection

be free of cracks and any blockage. Hydro-jet slots should be open and free of any blockage. Any damage, such as cracks, restriction due to deformation, or uninten- tional holes are not field repairable and the inlet nipple/diptube must be replaced.

Step 7. Upon completion of the inspection or subsequent replacement, reinstall the inlet nipple/diptube into the water heater. Connect the nipple to the plumbing system, resume water supply to the water heater, and refill the water heater.

Step 8. To resume operation, follow the instructions located on the water heater

Anode Inspection and ReplacementWARNING

Water heater components and stored water may be HOT when performing the following steps in this procedure. Take necessary precaution to prevent personal injury.

lighting instruction label. Or, use the lighting instructions located in the water heater installation and operating manual.

Anode Inspection and Replacement

Step 1. Move the gas control power switch to the “OFF” position

Step 2. Unplug the water heater from the wall outlet.

Step 3. Turn off the cold water supply to the water heater. Connect a hose to the drain valve of the water heater and route to an open drain. Open a nearby hot water faucet to vent the water heater for draining. Open the drain valve of water heater and allow the water heater to drain to a point below the outlet connection nipple.

Step 4. Disconnect the outlet nipple from the plumbing system.

Step 5. With an appropriate tool, such as a pipe wrench, remove the outlet nip- ple/anode from the water heater. Use caution not to damage the pipe threads.

Step 6. Visually inspect the outlet nipple/anode. The outlet nipple/anode should show signs of depletion, which is normal. If depletion is one-half the original anode diameter (approximately 3/4” diameter), replacement is recommended. If any of the steel core of the anode is exposed, replacement is recommended.

Step 7. Upon completion of the inspection or subsequent replacement, reinstall the outlet nipple/anode into the water heater. Connect the nipple to the plumbing system, resume water supply to the water heater, and refill the water heater.

Page 45

45

Page 45
Image 45
Bradford-White Corp U2TW65T*FRN, UTW450S60FR*N, UTW465S60FR*N, U2TW50T*FRN, U1TW60T*FRN Anode Inspection and Replacement