Bradford-White Corp U2TW65T*FRN Blower Temperature Switch Testing, Blower Installation cont’d

Models: U1TW40S*FRN U2TW65T*FRN UTW450S60FR*N U1TW60T*FRN UTW465S60FR*N U1TW50S*FRN U2TW50T*FRN

1 52
Download 52 pages 26.11 Kb
Page 31
Image 31
Blower Temperature Switch Testing
Control access
cover
Locate the blower temperature switch.

Blower Temperature Switch Testing

Blower Installation (cont’d)

Step 11. Secure blower in place using mounting screws from step 7. Step 12. Reinstall exhaust adapter from step 4.

Step 13. Reinstall dilution air clip from step 5.

Step 14. Reconnect vent system to exhaust adapter. Step 15. Reconnect cords from step 6.

Step 16. Position gas control power switch to the “ON” position. Step 17. Verify proper blower operation.

Blower Temperature Switch Testing

Blower Installation (cont’d)WARNING

115 volt potential exposure. Use caution making voltage checks to avoid

personal injury.

Step 1. Move the gas control power switch to the “OFF” position.

Gas control power

switch

Step 2. Remove the three screws (Phillips screw driver) from control access cover on blower and remove cover.

Blower temperature

switch location

Step 3.

Air mixing

inlet

Page 31

31

Page 31
Image 31