Bradford-White Corp U1TW50S*FRN, UTW450S60FR*N, UTW465S60FR*N Pressure Switch Replacement

Models: U1TW40S*FRN U2TW65T*FRN UTW450S60FR*N U1TW60T*FRN UTW465S60FR*N U1TW50S*FRN U2TW50T*FRN

1 52
Download 52 pages 26.11 Kb
Page 27
Image 27
Pressure Switch Replacement
Gas control power
switch

Pressure Switch Replacement

Pressure Switch Replacement

Manual backgroundWARNING

115 volt potential exposure. Use caution making voltage checks to avoid

personal injury.

Step 1. Move the gas control power switch to the “OFF” position.

Step 2. Remove the three screws (Phillips screw driver) from the control access cover on the blower as- sembly and remove cover.

Control access

cover

Step 3. Carefully remove pressure switch from blower housing.

Control access

cover

Slide pressure switch in direction of arrow while tilting slightly away from blower housing

Step 4. Disconnect tubing from the pressure switch.

Pressure switch

tubing

Page 27

27

Page 27
Image 27