2.Remove control panel from enclosure and, without disconnecting wiring, set control panel aside (D, Figure 23).
3.Remove inverter from enclosure (E) and, without disconnecting wiring, set inverter assembly aside.
E
D
5.Locate fuel valve (F, Figure 25) inside of the generator enclosure.
6.Remove hoses (G) and loosen screw (H) to remove the fuel valve.
7.Install a new fuel valve using the above steps in reverse order.
H
F
G
Figure 23
4. Close vent on fuel cap. Carefully spread ends of generator housing to remove fuel tank (Figure 24) from unit. Set fuel tank aside.
ReproductionFigure 25
Fuel FilterThe fuel filter is located inside the fuel tank (See Figure 18) and can be accessed by removing fuel hose. If fuel is not fl wing properly, remove the filter and clean it with carb cleaner r other appropriate cleaner.
If fuel will not flow after cleaning, replace the filter.
Figure 24