3.Measure for 120 VAC ouput (C, Figure 62).

5.Then measure resistance across sub-windings (E, Figure 64).

C

Figure 62

If voltage is not measured, check for loose wiring.

Repair/replace as necessary.

E

Figure 64

If resistance is 0.15 - 0.30 Ω the windings are good.

If resistance is not to specifications, check wire connections, or repair/replace wires, then retest.

 

 

 

 

• If resistance is still not to specifications, replace the

4. Disconnect the main winding connector and measure

 

stator winding.

 

 

Reproduction

resistance across the windings (D, Figure 63).

 

 

 

 

 

No DC Output

 

D

 

1.

Press the DC c rcu breaker (A, Figure 65) and retest. If

 

Not

 

 

still no DC ou pu , proceed to Step 2.

 

 

 

 

 

for

 

 

 

Figure 63

 

 

 

 

• If resistance is 1.35 - 1.75 Ω the windings are good.

 

A

• If resistance is not to specifications, check wire

 

 

Figure 65

connections or repair/replace wires, then retest.

 

 

If resistance is still not to specifications, proceed to

Step 5.

30