Cord Sets and Receptacles

Cord Sets and Receptacles

Use only high quality, well-insulated, grounded extension cords with the generator’s 120 Volt duplex receptacle. Inspect extension cords before each use.

Check the ratings of all extension cords before you use them. Extension cord sets used should be rated for 125 Volt AC loads at 20 Amps or greater for most electrical devices. Some devices, however, may not require this type of extension cord. Check the operator’s manuals of those devices for the manufacturer’s recommendations.

Keep extension cords as short as possible to minimize voltage drop.

120/240 Volt AC, 20 Amp, Locking Receptacle WARNING Overloaded electrical cords can overheat,

arc, and burn resulting in death, bodily injury, and/or property damage.

ONLY use cords rated for your loads.

Follow all safeties on electrical cords.

120/240 Volt AC, 20 Amp, Locking Receptacle

Use a NEMA L14-20 plug with this receptacle. Connect a

4-wire cord set rated for 250 Volt AC loads at 20 Amps (or greater). You can use the same 4-wire cord if you plan to run a 120 Volt load.

NEMA L14-20 4-Wire Cord Set

240V

120 Volt AC, 30 Amp Locking Receptacle 120V NEMA L5-30120 Volt AC, 20 Amp, Duplex Receptacles 120V 12 Volt DC, 10 Amp Receptacle

W (Neutral)

Y (Hot)

X (Hot)

NEMA L14-20

Ground (Green)

This receptacle powers 120/240 Volt AC, 60 Hz, single phase loads requiring up to 4,000 watts of power (4.0 kW) at

16.6Amps for 240 Volts or two independent 120 Volt loads at 16.6 Amps each. The outlet is protected by a 2 pole GFCI circuit breaker.

NOTICE Receptacles may be marked with rating value greater than generator output capacity.

NEVER attempt to power a device requiring more amperage than generator or receptacle can supply.

DO NOT overload the generator. See Don’t Overload Generator.

120 Volt AC, 30 Amp Locking Receptacle

Use a NEMA L5–30 plug with this receptacle. Connect a 3–wire cord set rated for 125 Volt AC loads at 30 Amps to the plug.

3-Wire Cord Set

NEMA L5-30

Neutral

120V

Hot

Manual backgroundManual backgroundManual background Ground (Green)

Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 3,600 watts (3.6 kW) of power at 30 Amps. The outlet is protected by a 2 pole GFCI circuit breaker.

120 Volt AC, 20 Amp, Duplex Receptacles

The duplex receptacle is protected against overload by a 2 pole GFCI circuit breaker.

Use each receptacle to operate 120 Volt AC, single-phase,

60 Hz electrical loads requiring up to 2,400 watts (2.4 kW) at 20 Amps of current. Use cord sets that are rated for 125 Volt AC loads at 20 Amps (or greater). Inspect cord sets before each use.

12 Volt DC, 10 Amp Receptacle

This receptacle allows you to recharge a 12 Volt automotive or utility style storage battery with the battery charge cables provided.

This receptacle can not recharge 6 Volt batteries and can not be used to crank an engine having a discharged battery. See the section Charging a Battery before attempting to recharge a battery.