Briggs & Stratton PRO4000 manual Operation, Starting the Engine, Connecting Electrical Loads

Models: PRO4000

1 84
Download 84 pages 9.15 Kb
Page 13
Image 13
Operation

Operation

Starting the Engine

Disconnect all electrical loads from the generator. Use the following start instructions:

1. Make sure unit is on a level surface.

NOTICE Failure to start and operate the unit on a level surface will cause the unit not to start or shut down during operation.

2. Turn the fuel valve (A) to the “On” position.

AStarting the EngineConnecting Electrical LoadsManual background

3.Make sure idle control switch is in “Off” position.

4.Push engine rocker switch to run position (I).

5.Push choke lever (B) to “Choke” position.

B

6.Grasp recoil handle and pull slowly until slight resistance is felt. Then pull rapidly one time only to start engine.

If engine starts, proceed to step 8.

If engine fails to start, proceed to step 7.

Manual background WARNING Starter cord kickback (rapid retraction) can result in bodily injury. Kickback will pull hand

and arm toward engine faster than you can let go.

Broken bones, fractures, bruises, or sprains could result.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

NEVER start or stop engine with electrical devices plugged in and turned on.

7.Move choke lever to “Half” choke position, and pull recoil handle twice.

• If engine fails to start, repeat steps 5 thru 6.

8.Slowly move choke lever to “Run” position. If engine falters, move choke lever to “Half” choke position until engine runs smoothly, and then to “Run” position.

NOTICE If engine floods, move choke lever to “Run” position and crank until engine starts.

NOTICE If engine starts after 3 pulls but fails to run, or if unit shuts down during operation, make sure unit is on a level surface and check for proper oil level in crankcase. This unit may be equipped with a low oil protection device. If so, oil must be at proper level for engine to start.

Manual background WARNING Contact with muffler area can result in serious burns.

Exhaust heat/gases can ignite combustibles, structures or damage

fuel tank causing a fire.

DO NOT touch hot parts and AVOID hot exhaust gases.

Allow equipment to cool before touching.

Keep at least 5 feet (152 cm) of clearance on all sides of generator including overhead.

It is a violation of California Public Resource Code, Section 4442, to use or operate the engine on any forest-covered, brush-covered, or grass-covered land unless the exhaust system is equipped with a spark arrester, as defined in Section 4442, maintained in effective working order. Other states or federal jurisdictions may have similar laws.

Contact the original equipment manufacturer, retailer, or dealer to obtain a spark arrester designed for the exhaust system installed on this engine.

Replacement parts must be the same and installed in the same position as the original parts.

Connecting Electrical Loads

1.Let engine stabilize and warm up for a few minutes after starting.

2.Plug in and turn on the desired 120 and/or 240 Volt AC, single phase, 60 Hz electrical loads.

NOTICE

DO NOT connect 240 Volt loads to the 120 Volt duplex receptacles.

DO NOT connect 3-phase loads to the generator.

DO NOT connect 50 Hz loads to the generator.

DO NOT OVERLOAD THE GENERATOR. See Don’t Overload Generator.

NOTICE Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

DO NOT exceed the generator’s wattage/amperage capacity. See Don’t Overload Generator in the Operation section.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.