ABOUT THESE UNITS

!WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSERVE THE FOLLOWING:

1.This unit is intented for residential installation only.

2.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.

3.Before replacing filters, servicing or cleaning unit, disconnect power cord from electrical outlet.

4.Installation must be done in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

5.This unit is not designed to provide combustion and/or dilution air for fuel-burning appliances.

6.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

7.Do not use this unit with any solid-state speed control device other than optional wall controls C12, CM, C34 and CMR (sold separately).

8.This unit must be grounded. The power supply cord has a 3-prong grounding plug for your personal safety. It must be plugged into a mating 3-prong grounding receptacle, grounded in accordance with the national electrical code and local codes and ordinances. Do not remove the ground prong. Do not use an extension cord.

9.Do not install in a cooking area or connect directly to any appliances.

10. Do not use to exhaust hazardous or explosive materials and vapors.

CAUTION

1.To avoid prematurate clogged filters, turn OFF the unit during construction or renovation.

2.Please read specification label on product for further information and requirements.

3.For HEPA 2000, HF 2.0, HEPA 3000, HF 3.0 and HEPA 4000 units only: Be sure to duct air outside – Do not intake / exhaust air into spaces within walls or ceiling or into attics, crawl spaces, or garage.

4.Itended for residential installation only in accordance with the requirements of NFPA 90B.

5.Do not run any air ducts directly above or closer than 2 ft (0.61 m) to any furnace or its supply plenum, boiler, or other heat producing appliance. For HEPA 2000, HF 2.0, HEPA 3000, HF 3.0 and HEPA 4000 units only, if a duct has to be connected to the furnace return plenum, it must be connected not closer than 9’10” (3 m) from this plenum connection to the furnace. For HEPA 1000 and HF 1.0 units only, the distance must be not closer than 2’ (0.61 m).

6.The ductwork is intended to be installed in compliance with all local and national codes that are applicable.

- 3 -

Page 3
Image 3
Broan HEPA 1000, HEPA 4000, HEPA 3000, HEPA 2000 installation instructions About These Units