4.INSTALL THE UNIT (CONT’D)
4.7INSTALLING DUAL EXTERIOR HOOD*
(HEPA 2000, HF 2.0, HEPA 3000, HF 3.0 AND HEPA 4000 UNITS ONLY)
4.7.1ASSEMBLING DUAL EXTERIOR HOOD
Exterior dual hood is coming in separate |
| |
parts. Using 2 #8 x 3/4” screws, assemble the |
| |
top metal screen and the plastic grille to the |
| |
dual exterior hood. Then, slide the bottom |
| |
metal screen to the dual exterior hood. See |
| |
illustration beside. |
| |
VO0024 |
| |
*Patent pending |
| |
4.7.2 LOCATING THE DUAL EXTERIOR HOOD |
| |
The dual exterior hood must be installed at a minimum |
| |
distance of 18 inches (457 mm) from the ground. | 18'' | |
See illustration beside. | ||
(457 mm) | ||
| ||
| VD0083 |
!WARNING
0
Make sure this hood is at least 3 feet (0.9 m) away from any of the following:
•High efficiency furnace vent.
•Gas meter exhaust, gas
•Any exhaust from a combustion source.
•Garbage bin and any other source of contamination.
4.7.3CONNECTING TANDEM® TRANSITION TO THE DUAL EXTERIOR HOOD
1.Using a jig saw, cut a 6’’ diameter hole in the exterior wall and insert the Tandem® transition through this hole.
1 |
VD0084 |
1) EXHAUST AIR TO OUTSIDE duct
CAUTION
The Tandem® transition must be inserted in such a way that the EXHAUST AIR TO OUTSIDE duct will be located on the top.
- 25 -