Appendix

Bar code human readable line ON or OFF

n = ‘r0’ or ‘R0

 

Human readable line OFF

n = ‘r1’ or ‘R1

 

Human readable line ON

Preset:

Human readable line ON

 

(1)

‘T5’ or ‘t5’

 

(2)

‘T6’ or ‘t6’

 

(3)

‘T130’ or ‘t130’

 

(4)

‘T131’ or ‘t131’

Preset:

Human readable line OFF

 

 

All others

A

 

 

This parameter shows whether the machine prints the human readable line below the bar code. Human readable characters are always printed with OCR-B font of 10 pitch and all the current character style enhancements are masked. The default setting is determined by the bar code mode selected by ‘t’ or ‘T’.

Quiet zone

n = ‘onnn’ or ‘Onnn’ (nnn = 0 ~ 32767)

Quiet zone is the space on both sides of the bar codes. Its width can be shown using the units that are set by the ‘u’ or ‘U’ parameter. (For the description of ‘u' or ‘U' parameter, see the next section.) The default setting of the quiet-zone width is 1 inch.

Bar code, expanded character unit, line block drawing and box drawing

n = ‘u0’ or ‘U0’

mm (preset)

n = ‘u1’ or ‘U1’

1/10

n = ‘u2’ or ‘U2’

1/100

n = ‘u3’ or ‘U3’

1/12

n = ‘u4’ or ‘U4’

1/120

n = ‘u5’ or ‘U5’

1/10 mm

n = ‘u6’ or ‘U6’

1/300

n = ‘u7’ or ‘U7’

1/720

This parameter shows the measurement units of X-axis offset, Y-axis offset, and bar code height.

Bar code, expanded character, line block drawing and box drawing offset in X-axis

n = ‘xnnn’ or ‘Xnnn’

This parameter shows the offset from the left margin in the ‘u’- or ‘U’-specified unit.

136