Differential feed

This serger is equipped with two sets of feed dogs under the presser foot to move the fabric through the machine. The differential feed controls the movement of both the front and the rear feed dogs. When set at 1, the feed dogs are moving at the same speed (ratio of 1). When the differential feed ratio is set at less than 1, the front feed dogs move slower than the rear feed dogs, stretching the fabric as it is sewn. This is effective on lightweight fabric that may pucker. When the differential feed ratio is set at greater than 1, the front feed dogs move faster than the rear feed dogs, gathering the fabric as it is sewn. This function assists in removing the rippling when serging stretch fabrics.

Differential feed adjustment

Feed Main Differential Effect Application ratio feed feed

(rear) (front)

 

Material is

Prevents thin

0.7 - 1.0

materials from

 

pulled tight.

puckering

 

Without

Normal

1.0

differential

 

feed.

sewing

 

 

 

Material is

Prevents

1.0 - 2.0

stretch

gathered or

materials from

 

pushed

 

stretching or

 

together.

 

puckering

 

 

The normal setting is 1.0 on the differential feed adjustment dial.

To adjust the diffrerential feed, turn the dial on the right bottom of the body.

<A>

1

2

1 Less than 1.0 2 Greater than 1.0 <A> Selection mark

An example

When stretch material is sewn without using the differential feed, the edge will be wavy.

English

To get smooth finish, adjust the feed ratio from 1.0 toward 2.0.

(The feed ratio required depends on the elasticity of the material.)

The more elastic the material, the further toward 2.0 the differential feed ratio should be set. Test sew with a scrap of the fabric to find the correct adjustment.

CAUTION

When sewing thick non-stretchable material such as denim, do not use the differential feed as it may damage the fabric.

Adjusting the presser foot pressure

Turn the pressure adjustment screw on the top left of the machine. You can adjust by reffering the value on the screw.

The normal setting is "2".

1

2

<A>

1 Less pressure

2 More pressure <A> Selection mark

7