Bryant 619CNF, 619CNQ installation instructions System Matches, Application Range

Models: 619CNQ 619CNF

1 24
Download 24 pages 52.51 Kb
Page 2
Image 2
Table 1 — System Matches

Table 1 — System Matches

SYSTEM TYPE

INDOOR SECTION NUMBER

OUTDOOR SECTION NUMBER

 

619CNF

538ANR,APR,AER

 

024*

018

 

024

024

Cooling Only

036

030

 

036

036

 

048

048

 

060

060

 

619CNQ

538BNR,BPR,BER

 

024*

018

 

024

024

Heat Pumps

036

030

 

036

036

 

048

048

 

060

060

 

619CNQ

538ANR,APR,AER

 

024*

018

 

024

024

Heating/Cooling

036

030

 

036

036

 

048

048

 

060

060

*Units must be field reconfigured for 11/2 ton (18,000 Btuh) operation. See Before Installation section on page 3 for details. NOTE: Numbers in ( ) indicate quantities when there is more than one fan coil unit in the system.

Ensure unit operation within the application guidelines shown in Table 2. When installing the outdoor unit, for cool- ing operation when the outdoor-air temperature is below

55 F, the following accessories are required:

low ambient kit

crankcase heater

winter start kit

isolation relay (538B heat pump units only)

This will provide cooling operation down to 40 F ambient temperature. For operation down to –20 F ambient tempera- ture, a field-installed wind baffle will also be required.

To complete installation of the system, the following items must be field-supplied for connection of the indoor and outdoor units:

refrigerant piping

condensate drain piping

thermostat

wiring

For some applications, a fresh air intake, power vent fan, and/or condensate pump kit may be required. Refer to Tables 3A and 3B for physical data.

Table 2 — Application Range

COOLING

Maximum

Minimum

Indoor

 

Outdoor

Indoor

 

Outdoor

95 F DB

 

125 F DB

67 F DB

 

55 F DB*

71 F WB

 

 

57 F WB

 

40 F DB

 

HEATING (Heat Pump Systems Only)

 

Maximum

Minimum

Indoor

 

Outdoor

Indoor

 

Outdoor

80 F DB

 

75 F DB

55 F DB

 

–20 F DB

71 F WB

 

65 F WB

 

 

 

LEGEND

DB — Dry Bulb

WB — Wet Bulb

*This value is for single-zone systems and may be equipped with an accessory low-ambient control or winter start kit that will allow opera- tion down to 20 F.

—2—

Page 2
Image 2
Bryant 619CNF, 619CNQ installation instructions System Matches, Application Range