TROUBLESHOOTING (cont.) |
|
|
|
PROBLEM |
| PROBABLE CAUSE | |
Automatic refill will not operate | 1. | No water | |
or display shows FILL TIME TOO |
|
|
|
LONG | 2. | Tank drain clamp | |
| |||
| 3. | Water Strainer |
REMEDY
Check plumbing and
Check tank drain clamp
Direction of flow arrow must be pointing towards direction of water flow.
4.Refill probe or Sensitivity set- ting
5.Refill valve
Remove the strainer and check for obstructions. Clear or replace.
Check the sensitivity setting. Refer to the REFILL function on page
47.If the left three digit number is less than the right number, the machine “thinks” it is full and the refill valve should be off. If the left number is larger than the right, then the refill valve will automatically be turned on to fill the tank. The right number is the threshold setting and can be adjusted to compensate for extreme water conditions: very pure, low conductance water requires a higher setting, while high mineral content, high conductance water requires a lower setting. Note that the left number changes from a high value when water is NOT touching the refill probe to a low valve when water IS touching the probe. For best operation, the right number should be set to a value midway between these low and high numbers. Be- fore changing the setting, confirm that the refill probe is free of scale buildup and the connection to it is
Page 66 | 36748 080904 |
|