TROUBLESHOOTING (cont.)

 

 

 

 

 

PROBLEM

 

PROBABLE CAUSE

 

REMEDY

Dilution cycle will not start

1.

Dilution valve

 

Test the dilution valve. Refer to

 

 

 

 

 

the test outputs procedures on

 

 

 

 

 

page 56.

 

2.

Recipe settings

 

Check to make sure the current

 

 

 

 

 

recipe has a dilution volume set.

 

 

 

 

 

Coffee recipes will not have dilu-

 

 

 

 

 

tion.

 

3.

Strainer

 

Direction of flow arrow must be

 

 

 

 

 

pointing towards the brewer. Re-

 

 

 

 

 

move the strainer and check for

 

 

 

 

 

obstructions. Clear or replace.