PROGRAMMING THE BREWER (cont.)

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

Procedure to test switches:

The following switches can be individually tested: Half Batch

Full Batch

Left Hidden Brew A Brew B Brew C

SERVICE TOOLS?

NO YES

PRESSING NO WILL

BREW

BREW

BREW

ADVANCE TO

A

B

C

FACTORY DEFAULTS

 

 

 

 

 

 

 

 

 

 

On/Off

1.Press and hold the right hidden button until the dis- play reads SET LANGUAGE. Press the right hidden button until the display reads SERVICE TOOLS.

2.Press and release YES. The display should now read TEST OUTPUTS? Press and release NO to advance to TEST SWITCHES.

3.Press and release YES. The display should now read RIGHT HIDDEN TO EXIT, and then NOTHING

PRESSED.

4.From this screen, press any of the switches on the front of the brewer. While the switch is pressed, the display shows the name of that switch. If the name does not appear, or if it remains after the switch has been released, the switch is defective. Each switch can be tested in this manner.

After all switches have been tested, press and release the right hidden button to return to the TEST SWITCHES screen. To exit programming, press and release the ON/OFF button to return to the MAIN SCREEN.

PRESSING NO WILL

ADVANCE TO

TEST FREQUENCY

TEST OUTPUTS?

NO YES

BREW

BREW

BREW

A

B

C

TEST SWITCHES?

NO YES

BREW

BREW

BREW

A

B

C

RIGHT HIDDEN

TO EXIT

NOTHING PRESSED

AFTER ALL SWITCHES ARE TESTED PRESS RIGHT HIDDEN TO RETURN TO TEST SWITCHES

TEST SWITCHES?

NO YES

BREW

BREW

BREW

A

B

C

TEST FREQUENCY?

NO YES

P2884

Page 58

36748 041504