TROUBLESHOOTING (cont.)PROBLEMTemperature Too LowHeating Time Too LongFill Time Too LongTemp Sensor Out Of Range, Check For Bad ConnectionsTemp Sensor Out Of Range, Check Wire For ShortsEquipment will not operate
PROBABLE CAUSE1.Water temperature in the tank does not meet the ready tempera- ture.1.Tank Heater failure.2.Control Board/Thermistor fail- ure1.Water shut off to brewer2.Tank Drain clamp is shut3.Inlet Solenoid failure4.Control Board Failure5.ON/OFF switch is OFF1.Temperature Sensor Probe wire(s) broken or not making con- nection1.Temperature Sensor Probe wire(s) shorted to housing or to each other.1. No power or incorrect voltage
REMEDYA)Wait for the brewer to heat to the proper temperature.B)Disable the BREW LOCKOUT function. See page 17 for proce- dure.Service required

Service required

Check water supply shut-offCheck tank drain clampService Required

Service Required

Turn switch ON

Check wire and connection of both blackandwhitewiresoftemperature probe.

Check to confirm that wire(s) are not pinched between two surfaces or connected to each other.

Measure the voltage at the terminal block and confirm that it matches the voltage specified on the brewer data plate withing +/- 10%.

Page 64

36748 051304