Image 17
BREWING CIRCUIT

TROUBLESHOOTING (cont.)

 

 

BREWING CIRCUIT

 

 

PROBLEM

 

PROBABLE CAUSE

Brew cycle will not start

 

1. Display flashing

2. No water

3. No power or incorrect voltage to the brewer

4. ON/OFF switch not in the "ON" position

5. Low water temperature (Brew lockout is enabled)

6. Water not touching refill probe inside tank

7. Switch panel

REMEDY

Brewer has shut down due to malfunction (See Diagnostic Chart in manual, Page 21, or under top lid of brewer).

Water lines and valves to the brewer must be open.

Check for voltage across the black and white terminals at the termi- nal block.

The indicator lamp must be lit

Allow brewer to heat until ready lamp is lit, or disable the brew lockout feature. (See page 8)

Press ON/OFF switch (indicator must be lit). Brewer will refill until water touches probe inside tank. Water must be in contact with refill probe before brew cycle will start.

Disconnect the brewer from the power source. Disconnect the rib- bon connector from the control board. Check for continuity be- tween pins 1 & 2 (An arrow on the connector indicates pin 1). No continuity should be present. Press the BREW switch. Continuity should be present for as long as the switch is held "ON". If no con- tinuity is present, replace the switch membrane decal.(See page 24)

Page 17

35582 041503

 

Page 17
Image 17
Bunn CDBCF, S/N CDBC020213 Brewing Circuit, Brew cycle will not start, Display flashing, Problem, Probable Cause, Remedy