TROUBLESHOOTING (cont.) |
|
|
| |
BREWING CIRCUIT (cont.) |
|
|
| |
PROBLEM |
| PROBABLE CAUSE |
| REMEDY |
Dry coffee grounds remain in the | 1. Sprayhead |
| Make sure sprayhead is present | |
funnel |
|
| and holes are clear and unob- | |
|
|
|
| structed. |
|
| 2. Funnel loading |
| The BUNN¨ paper filter must be |
|
|
|
| centered in the funnel and the bed |
|
|
|
| of grounds leveled by shaking gen- |
|
|
|
| tly. |
Low beverage serving tempera- | 1. Warmer |
| Disconnect the brewer from the | |
ture |
|
| power source. Remove the warmer | |
|
|
|
| plate and turn upside down to ex- |
|
|
|
| pose the warmer terminals. Re- |
|
|
|
| move the two wires. Check for |
|
|
|
| continuity across the two warmer |
|
|
|
| terminals. If continuity is not |
|
|
|
| present, replace the warmer ele- |
|
|
|
| ment (See page 30). If continuity |
|
|
|
| is present, reconnect the wires to |
|
|
|
| the warmer element. Check for |
|
|
|
| voltage at the warmer terminals. |
|
|
|
| Turn the warmer switch "ON". The |
|
|
|
| indicator light will come on. Volt- |
|
|
|
| age should be present at the ter- |
|
|
|
| minals. If not, disconnect power |
|
|
|
| supply and check wiring and |
|
|
|
| switch. |
Page 20 | 35582 041503 |
|