Bunn S/N CDBC020213 Cdbc, Single Cd Adjustments & Optional Settings, Setting Brew Temperature

Models: CDBCP CDBCFP CDBCF S/N CDBC020213

1 35
Download 35 pages 47.44 Kb
Page 8
Image 8
CDBC, SINGLE CD ADJUSTMENTS & OPTIONAL SETTINGS

CDBC, SINGLE CD ADJUSTMENTS & OPTIONAL SETTINGS

HIDDEN

SWITCH

P1866

Setting Brew Temperature

The brewer is factory set to brew at 200°F (93ûC). To change this setting, press and hold the "HIDDEN" switch beneath the "¨". The word "TEMP" above the "ON/OFF" switch will glow to correspond with the temporary function change of this switch. Repeatedly press and release the "ON/OFF" switch until one of the bank of temperature indicators shows the approximate desired temperature. When two indicators are glowing, the temperature is approximately the number between them.

Setting Brew Lockout

The brewer is factory set with the brew lockout disabled. Brew lockout prevents starting a brew cycle if the ready indicator is not glowing. When an attempt at brewing cannot be allowed, the word "NOT" and "LOCKOUT" flash for three seconds to indicate the reason the brew can't begin. To change the condition of the brew lockout, press and hold the "HIDDEN" switch beneath the "¨" and momentarily press the "BREW" switch.

Adjusting Automatic Warmer Shut-Off

The brewer is factory set with this feature disabled. The automatic warmer shut-off deenergizes all warmers after a predetermined time period after the most recent brew cycle. To change the setting, press and hold the "BREW" switch and the "HIDDEN" switch beneath the "¨" for five seconds, the entire bank of temperature indicators will flash on-and-off. Release both switches. Pressing and releasing the "BREW" switch will select the number of temperature indicators from none to five. When no indicators are glowing, this feature is disabled and all warmers will be controlled only by their respective switches. When one of five indicators are glowing, it indicates the approximate number of hours of delay before all warmers will be automatically deenergized after the most recent brew cycle.

IMPORTANT: The tank must be full and fill solenoid shut off prior to making these adjust- ments.

Adjusting Brew Volumes

CDBC models are factory set to deliver 64 ounces ± 2 for each brew cycle.

SINGLE CD models are factory set to deliver 128 ounces ± 2 for each brew cycle when 1 gal. option is selected and 64 ounces ± 2 for each brew cycle when 1/2 gal. option is selected.

Page 8

35582 041503

 

Page 8
Image 8
Bunn S/N CDBC020213, CDBCF Cdbc, Single Cd Adjustments & Optional Settings, Setting Brew Temperature, Setting Brew Lockout