CDBC, SINGLE CD ADJUSTMENTS & OPTIONAL SETTINGS
HIDDEN |
SWITCH |
P1866 |
Setting Brew Temperature
The brewer is factory set to brew at 200°F (93ûC). To change this setting, press and hold the "HIDDEN" switch beneath the "¨". The word "TEMP" above the "ON/OFF" switch will glow to correspond with the temporary function change of this switch. Repeatedly press and release the "ON/OFF" switch until one of the bank of temperature indicators shows the approximate desired temperature. When two indicators are glowing, the temperature is approximately the number between them.
Setting Brew Lockout
The brewer is factory set with the brew lockout disabled. Brew lockout prevents starting a brew cycle if the ready indicator is not glowing. When an attempt at brewing cannot be allowed, the word "NOT" and "LOCKOUT" flash for three seconds to indicate the reason the brew can't begin. To change the condition of the brew lockout, press and hold the "HIDDEN" switch beneath the "¨" and momentarily press the "BREW" switch.
Adjusting Automatic Warmer Shut-Off
The brewer is factory set with this feature disabled. The automatic warmer
IMPORTANT: The tank must be full and fill solenoid shut off prior to making these adjust- ments.
Adjusting Brew Volumes
CDBC models are factory set to deliver 64 ounces ± 2 for each brew cycle.
SINGLE CD models are factory set to deliver 128 ounces ± 2 for each brew cycle when 1 gal. option is selected and 64 ounces ± 2 for each brew cycle when 1/2 gal. option is selected.
Page 8 | 35582 041503 |
|