TROUBLESHOOTING (cont.) |
|
|
|
PROBLEM | PROBABLE CAUSE | REMEDY | |
Water running out of the overflow | 1. | Brewer not level | Brewer must be level and installed |
|
|
| on a sturdy structure. |
| 2. | Solenoid Valve | Refer to Service - Solenoid Valve |
|
|
| for testing procedures. See page |
|
|
| 23 |
| 3. | Liquid Level Board | Refer to Service |
|
|
| Board for testing procedures. See |
|
|
| page 18 |
| 4. | Probe |
Water is not hot | 1. | Limit Thermostat |
CAUTION - Do not eliminate or bypass limit thermostat. Use only
Refer to Service - Probe for test- ing procedures. See page 18
Refer to Service - Limit Thermo- stat for testing procedures. See page 17
| 2. | Control Thermostat | Refer to Service - Control Ther- |
|
|
| mostat for testing procedures. See |
|
|
| page 15 |
| 3. | Tank Heater | Refer to Service - Tank Heater for |
|
|
| testing procedures. See page 26 |
| 4. | Contactor | Refer to Service - Contactor for |
|
|
| testing procedures. See page 14 |
| 5. | Thermal fuses | Refer to Service - thermal fuses |
|
|
| for testing procedures. See page |
|
|
| 27 |
Fuse Opening | 1. Fuse | Refer to Service - Fuse for testing | |
|
|
| procedures. See page 16 |
| 2. | Tank Heater | Refer to Service - Tank Heater for |
| testing procedures. See page 26 |
Page 10 | 10067.3 070102 |
|