Bunn SRUA service manual SERVICE cont DIGITAL BREW TIMER Late Models

Models: SRUA

1 31
Download 31 pages 26.72 Kb
Page 29
Image 29
SERVICE (cont.)

SERVICE (cont.)

DIGITAL BREW TIMER (Late Models)

LATE MODELS

P2211.40

FIG. 29 DIGITAL BREW TIMER

Location:

The timer is located inside the front of the trunk on the top of the component bracket.

Test Procedure.

NOTE: Do not remove or install wires while timer board is installed. Pressure applied to one side may cause damage to the board.

1.Disconnect the brewer from the power source and remove the front access panel.

2.Remove the two #8-32 screws securing circuit board to the mounting bracket.

3.Remove circuit board and spacers (as required).

4.With a voltmeter, check the voltage across termi- nals TL1 and TL2 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source. The indication must be 230 volts ac.

5.Disconnect the brewer from the power source.

If voltage is present as described, proceed to #6.

If voltage is not present as described, refer to the Wiring Diagrams and check the brewer wiring har- ness.

6.With a voltmeter, check the voltage across termi- nals TL1 and TL4 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source. The indication must be 0 volts.

If voltage is as described, proceed to #7.

If voltage is not as described, disconnect the brewer from the power source and replace the timer.

7.With a voltmeter, check the voltage across termi- nals TL1 and TL4 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source and press the "START" switch. The indica- tion must be 230 volts ac.

If voltage is present as described, the brew timer is operating properly. Reset the timer as required, to obtain the desired brew volume.

If voltage is not present as described, disconnect the brewer from the power source and replace the timer.

Removal and Replacement:

1.Remove the two #8-32 screws securing circuit board to the mounting bracket.

2.Remove circuit board and spacers (as required).

3.Remove all wires from the timer.

4.Attach all wires to the replacement timer board prior to installation to the component mounting bracket. Refer to FIG. 30 when reconnecting the wires.

5.Install new circuit board with spacers (as re- quired) to the component mounting bracket.

6.Adjust the timer as described below.

Timer Setting:

NOTE: Prior to setting or modifying volumes, check that the brewer is connected to water supply, the tank is properly filled, and a funnel support, funnel and funnel cover are in place.

NOTE: All volume settings must be done with the swing spout shield installed.

1.Modifying brew volumes. To modify a brew vol- ume, first check that the SET/LOCK switch is in the “SET” position on the circuit board.

To increase a brew volume, place the ON/OFF switch in the “ON” position, press and hold the START switch until you see three breaks in the water stream from the swing arm. Release the switch and press it again one or more times. (Failure to release the switch

Page 29

10067.3 070102

 

Page 29
Image 29
Bunn SRUA service manual SERVICE cont DIGITAL BREW TIMER Late Models