SERVICE (cont.)
FUSE AND FUSE HOLDER
P2176.30 |
FIG.6 FUSE AND FUSE HOLDER |
Location: |
The fuse and fuse holder are located on the rear of the urn behind the rear utility cover.
Test Procedures:
1.Disconnect the brewer from the power source.
2.Remove the cap and fuse from the fuse holder.
3.Remove fuse from the cap.
4.Check for continuity through the fuse.
If continuity is present as described, reinstall the fuse, the fuse is operating properly.
If continuity is not present as described replace the fuse.
Removal and Replacement:
Fuse:
1.Remove the cap from the fuse holder.
2.Remove fuse from the fuse holder, inspect, if blown discard.
3.Install new 5 amp fuse in the fuse holder.
4.Reinstall fuse holder cap.
Fuse Holder:
1.Disconnect the wires from the rear of the fuse holder.
2.Remove the nut securing the fuse holder to the component bracket.
3.Push fuse holder through the hole in the compo- nent bracket.
4.Install new fuse holder and fuse through the hole in the component bracket and secure with nut.
5.Refer to Fig. 7 and reconnect the wires.
RED from ON/OFF Switch
RED from Main Harness
P2112
FIG. 7 FUSE HOLDER TERMINALS