TROUBLESHOOTING (cont.)
PROBLEM
Brew cycle will not start (cont.)
Tank not filling
PROBABLE CAUSE
6.Start Switch
7.Timer
8.Pump
9.Solenoid Valve
10.Strainer
1.ON/OFF Switch (This switch must be in the "ON" position for the refill circuit to operate.
2. No water
REMEDY
Refer to Service - Start Switch for testing procedures. See page 24
Refer to Service - Timer for testing procedures. See page 28 or 29
Refer to Service - Pump for testing procedures. See page 21
Refer to Service - Solenoid Valve for testing procedures. See page 23
(A)Direction of flow arrow must be pointing towards brewer.
(B)Remove the strainer and check for obstructions. Clear or replace.
Refer to Service - ON/OFF Switch for testing procedures. See page 20
Be sure water
3.Solenoid Valve
4.Probe
5.Liquid Level Board
Refer to Service - Solenoid Valve for testing procedures. See page 23
Refer to Service - Probe for testing procedures. See page 18
Refer to Service - Liquid Level Board for testing procedures. See page 18
Page 9 | 10067.3 070102 |
|