Bunn SRUA service manual TROUBLESHOOTING cont PROBLEM, Probable Cause, Remedy

Models: SRUA

1 31
Download 31 pages 26.72 Kb
Page 9
Image 9

TROUBLESHOOTING (cont.)

PROBLEM

Brew cycle will not start (cont.)

Tank not filling

PROBABLE CAUSE

6.Start Switch

7.Timer

8.Pump

9.Solenoid Valve

10.Strainer

1.ON/OFF Switch (This switch must be in the "ON" position for the refill circuit to operate.

2. No water

REMEDY

Refer to Service - Start Switch for testing procedures. See page 24

Refer to Service - Timer for testing procedures. See page 28 or 29

Refer to Service - Pump for testing procedures. See page 21

Refer to Service - Solenoid Valve for testing procedures. See page 23

(A)Direction of flow arrow must be pointing towards brewer.

(B)Remove the strainer and check for obstructions. Clear or replace.

Refer to Service - ON/OFF Switch for testing procedures. See page 20

Be sure water shut-off is open and that in-line filters or strainers are not blocking water flow.

3.Solenoid Valve

4.Probe

5.Liquid Level Board

Refer to Service - Solenoid Valve for testing procedures. See page 23

Refer to Service - Probe for testing procedures. See page 18

Refer to Service - Liquid Level Board for testing procedures. See page 18

Page 9

10067.3 070102

 

Page 9
Image 9
Bunn SRUA service manual TROUBLESHOOTING cont PROBLEM, Probable Cause, Remedy