SOLENOID

SERVICE (cont.)

SOLENOID

 

FIG. 18 SOLENOID

P2180

 

Location:

 

The solenoid is mounted on the upper left rear of the component bracket.

Test Procedures:

1.Drain 1/2 gallon of water from the faucet in order to activate the probe.

2.Disconnect the brewer from the power source.

3.Place the ON/OFF switch in the ON position.

4.Disconnect the blue wire from the liquid level board T1 and the black wire from the main harness to the solenoid. With a voltmeter, check the volt- age across the blue wire and the black wire. Connect the brewer to the power source. After an approximate 5 second delay, the indication must be 230 volts ac.

5.Disconnect the brewer from the power source.

If voltage is present as described, proceed to #6.

If voltage is not present as described, refer to the brewer wiring diagram and check the wiring harness.

6. Check for continuity across the solenoid valve coil

7.Check the solenoid valve for coil action. Connect the dispenser to the power source. Listen carefully in the vicinity of the solenoid valve for a "clicking" sound as the coil magnet attracts.

If the sound is heard as described and water will not pass through the solenoid valve, there may be a blockage in the water line before the solenoid valve or, the solenoid valve may require inspection for wear, and removal of waterborne particles.

If the sound is not heard as described, replace the solenoid valve.

Removal and Replacement:

1.Remove all wires from the solenoid valve.

2.Turn off the water supply to the brewer.

3.Disconnect the water inlet line from the connector on the solenoid valve.

4.Remove solenoid, connectors, and tank inlet tube as an assembly.

5.Remove the tank inlet tube grommet and discard.

6.Install new tank inlet tube grommet.

7.Install new solenoid assembly.

8.Install water inlet tube to connector on the sole- noid.

9.Turn on the water supply to the brewer.

10.Refer to Fig. 19 and reconnect the wires.

BLU from Liquid

Level Board T1

BLK from Main

Harness

GRN from Main

Harness

terminals.

If continuity is present as described, reconnect the wires to the solenoid.

If continuity is not present as described, replace the solenoid valve.

FIG. 19 SOLENOID TERMINALS

P1741.30