SERVICE (cont.)
TANK HEATER
P2180 |
FIG. 24 TANK HEATER |
Location: |
The tank heater is located on the front center of the upper component bracket.
Test Procedures:
1.Disconnect the brewer from the power source.
2.Disconnect the wires from the tank heater.
3.Check for continuity across the tank heater termi- nals.
If continuity is present as described, tank heater is operating properly.
If continuity is not present as described, replace the tank heater.
Removal and Replacement:
1.Remove the thermal fuses from the tank heater.
2.Remove the four
3.Remove tank heater and gasket.
4.Position new tank heater and gasket on the com- ponent bracket and secure with four
5.Refer to Fig. 25 and reconnect the wires.
|
| RED (Thermal Fuse) to | ||
|
| Contactor | Lower | Right |
|
| Terminal) |
|
|
BLK (Thermal Fuse) to |
|
| ||
Contactor | Lower | Left |
|
|
Terminal) |
|
|
|
|
|
|
|
| P1746 |
FIG. 25 TANK HEATER TERMINALS |
|
Page 26 | 10067.3 070102 |
|